OBJECT TO DETERMINE INITIAL AND
FINAL SETTING TIME
OF
CEMENT
IMPORTANCE The object is to distinguish between,quick setting and normal setting
OF TEST time and to detect the deterioration due to storage.
APPARATUS • Vicat Apparatus
• Balance (capacity 1000 gms,
accuracy 0.1 gm)
• Annular attachment of Vicat Apparatus
& HUMIDITY • Relative Humidity in Laboratory :
65 + 5 %
PROCEDURE On a non-porous platform
• Mix neat cement with
enough water
to give a paste of Standard
Consistency.
• Start stop watch immediately on adding water to cement. Note
Stop watch reading (To)
• Rest
Vicat mould on non-porous plate and fill it completely with
cement paste. Level of top surface and expel air
by shaking.
• Place test block with mould under the rod bearing needle of Vicat
apparatus and bring rod
level with
top of
test specimen.
Release needle slowly and let it
penetrate in the test block.
• Repeat
the procedure until needle stops of distance
of (5 +
0.5) mm from base of test block. Read the stop watch and note the time (T1).
• Replace needle
by
annular
attachment. Repeat
procedure of
releasing the needle till needle makes an impression on top of
test
block while attachment fails to do so.
Read the stop watch
and note time (T2).
CALCULATION Initial
Setting Time (IST) = (T1 – T0)
Final Setting Time (FST) = (T2 – T 0)
REPORTING Report IST & FST to nearest 5 minutes