(Clause 4.3)



IS Sieve
Designation
Percentage Passing for


Grading
Grading
Zone – II
Grading
Zone – III
Grading
Zone - IV
Zone – I

10 mm


100

100

100
100


4.75 mm


90 – 100

90 – 100

95 – 100
90 – 100


2.36 mm


75 – 100

85 – 100

95 – 100
60 – 95


1.18 mm


55 – 90

75 – 100

90 – 100
30 – 70


600 Micron


35 – 59

60 – 79

80 – 100
15 – 34


300 Micron


8 – 30

12 – 40

15 – 50
5 – 20


150 Micron


0 – 10

0 – 10

0 - 15
0 – 10






 